XenMatrix™ Grafts are created using the patented AquaPure™ Process which effectively removes cells while maintaining the structure and strength of the graft. The resulting open collagen scaffold allows early cellular infiltration and revascularization without a significant loss of strength during the early healing process as demonstrated in preclinical studies.1

Structure

  • Acellular non-crosslinked porcine collagen scaffold
  • Open collagen structure allows early cellular infiltration and revascularization as demonstrated in preclinical studies.1

XenMatrix™ Surgical Graft has almost 3x more open space than Strattice™ Firm.1

Repairing the abdominal wall with a strong, open collagen scaffold allows for early remodeling.
XenMatrix™ Surgical Graft,
H&E Stain 40x, 47% open space
Strattice™ Firm,
H&E Stain 40x, 16% open space

Strength

Preclinical studies demonstrated:

  • Demonstrated mechanical strength2
  • Maintains strength during the early healing process1

1Preclinical data on file, results may not correlate to clinical performance
2Deeken CR, Eliason B, Pichert M, Grant S, Frisella M, Matthews B. Differentiation of Biologic Scaffold Materials Through Physiomechanical, Thermal and Enzymatic Degradation Techniques. Ann Surg 2012. Mar; 255(3):595-604.

Performance

  • Peer reviewed clinical data2
  • 31 articles published in peer review journals since 20093


1Preclinical data on file, results may not correlate to clinical performance
2Deeken CR, Eliason B, Pichert M, Grant S, Frisella M, Matthews B. Differentiation of Biologic Scaffold Materials Through Physiomechanical, Thermal and Enzymatic Degradation Techniques. Ann Surg 2012. Mar; 255(3):595-604.
3Literature Search: Clinical publications with XenMatrix Surgical Graft, published in the last 5 years through 8/13, performed on Google Scholar and PubMed. Inclusion criteria, all preclinical and clinical studies published in peer-reviewed journals.

Ordering Information

    • 1161015
    • 1/cs.
    • 3.9” x 5.9” (10 cm x 15 cm) Rectangle
    • 1161020
    • 1/cs.
    • 3.9” x 7.9” (10 cm x 20 cm) Rectangle
    • 1161028
    • 1/cs.
    • 3.9” x 11” (10 cm x 28 cm) Rectangle
    • 1161520
    • 1/cs.
    • 5.9" x 7.9" (15 cm x 20 cm) Rectangle
    • 1161525
    • 1/cs.
    • 5.9” x 9.8” (15 cm x 25 cm) Rectangle
    • 1161928
    • 1/cs.
    • 7.5" x 11" (19 cm x 28 cm) Rectangle
    • 1161935
    • 1/cs.
    • 7.5" x 13.8" (19 cm x 35 cm) Rectangle
    • 1162020
    • 1/cs.
    • 7.9” x 7.9” (20 cm x 20 cm) Rectangle
    • 1162025
    • 1/cs.
    • 7.9” x 9.8” (20 cm x 25 cm) Rectangle
    • 1160606
    • 1/cs.
    • 2.4" x 2.4" (6 cm x 6 cm) Square
    • 1160610
    • 1/cs.
    • 3.9" x 2.4" (6 cm x 10 cm) Rectangle
    • 1160808
    • 1/cs.
    • 3.1" x 3.1" (8cm x 8cm) Square
    • 1160616
    • 1/cs.
    • 6.3" x 2.4" (6 cm x 16 cm) Rectangle
    • 1161010
    • 1/cs.
    • 3.9" x 3.9" (10 cm x 10 cm) Square
    • 1162040
    • 1/cs.
    • 7.9" x 15.8" (20 cm x 40 cm) Rectangle
    • 1163030
    • 1/cs.
    • 11.8" x 11.8" (30 cm x 30 cm) Square
    • 1162540
    • 1/cs.
    • 9.8" x 15.8" (25 cm x 40 cm) Rectangle
    • 1163045
    • 1/cs.
    • 11.8" x 17.7" (30 cm x 45 cm) Rectangle

Accessories

Indications
Intended for implantation to reinforce soft tissue where weakness exists and for surgical repair of damaged or ruptured soft tissue, including: abdominal plastic and reconstructive surgery; muscle flap reinforcement; hernia repair including abdominal, inguinal, femoral, diaphragmatic, scrotal, umbilical, and incisional hernias.

Contraindications
XenMatrix™Surgical Graft should not be used on patients with known sensitivity to porcine products. Not for reconstruction of cardiovascular defects. Not for reconstruction of central nervous system or peripheral nervous system defects. Use of this product in applications other than those indicated has the potential for serious complications.

Warnings
If an infection develops, it should be treated aggressively. An allergic reaction, which is unrelated to other therapy, is an indication to consider removal of XenMatrix™ Surgical Graft.

Precautions
Place device in maximum possible contact with healthy, well-vascularized tissue to promote cell ingrowth and tissue remodeling. When unable to close skin over the XenMatrix™ Surgical Graft, ensure that the implant remains moist. Avoid drying of the implant through “continued suction devices” as this may negatively impact the performance of the implant. Only physicians qualified in the appropriate surgical techniques should use this surgical graft. The surgeon should thoroughly understand the surgical procedure and the performance characteristics of the surgical graft.

Adverse Reactions
Potential complications with the use of any prosthesis may include, but are not limited to, allergy, seroma, infection, inflammation, adhesion, fistula formation, hematoma and recurrence of tissue defect.
 
Please consult package insert for more detailed safety information and instructions for use.